Making customers happy and providing the products and services they expect is the foundation of success of our business. Whether you need to inquire about one of our locations or you wish to learn more about any of our products this is the place to be.
Type of Analyser / Instruments |
Type of Gas Required |
Off Line Gas Chromatograph |
Process Gas Mixture Calibration Gas Mixture |
Different Analytical Instruments like AAS, OES, ICP, XRF, CHN etc |
PROGAS INSTRUMENT GRADE |
Process Application |
|
Petrochemical & Refineries |
Type of Analyser / Instruments |
Type of Gas Required |
On Line Gas Chromatograph |
Calibration Gas Mixture |
Off Line Gas Chromatograph |
PROGAS INSTRUMENT GRADE |
Explosimeter |
|
On Line Analyser for Oxygen, Moisture, Hydrocarbon, SOx,
NOx etc. |
Process Gas Mixture |
HPLC |
CO2 + N2 |
|
H2 + N2 |
|
CO + N2 |
|
Methane + Air |
|
Propane + Propylene |
|
Propylene + Hydrogen + CO |
|
Ethylene + Hydrogen + Propane + Propylene |
|
Ethane + Ethylene + Propylene + Butane + Nitrogen |
|
I-Pentane + N - Ethane + Methane + I- Butane + N - Butane + Ethane + Propane |
|
Ethylene + Ethane + Argon + Methane + CO + CO2 + N2 + H2 |
Type of Analyser / Instruments |
Type of Gas Required |
Different Analytical Instruments (OEM) |
Calibration Gas Mixture |
|
PROGAS INSTRUMENT GRADE |
Dedicated Analyzers |
CO Analyzer : CO in Nitrogen |
|
Trace Oxygen Analyzer : O2 in N2 |
|
Oxygen Analyzer : O2 in N2 |
|
Sulphur Dioxide Analyzer : SO2 in N2 |
|
Carbon Dioxide Analyzer : CO2 in N2 |
|
Nitrogen Analyzer : N2 in Argon |
|
Zero Setting : Zero Nitrogen, Zero Argon, Zero Oxygen, Zero Hydrogen, Zero Air |
|
Explosimeter : Propane, Methane, CO Mixtures in Air |
Atomic Absorption Spectrometry |
Fuel Gas : Acetylene, Hydrogen, Propane |
|
Oxidizer : Zero Air |
|
Calibration Gas : Methane in Air/N2/Argon |
Total Hydrocarbon Analyzer |
Fuel Gas : H2 in N2/He |
|
Oxidizer : Zero Air |
|
Calibration Gas : Methane in Air/N2/Argon |
Gas Chromatograph with FID |
Carrier Gas : Helium + Nitrogen |
|
Fuel Gas : H2 in N2/He |
|
Calibration Gas : 10 ppm CH4, 10 ppm C2H6, 10 ppm 1- 4H10 |
Gas Chromatograph with ECD |
Carrier Gas : Methane in Argon, H2 in Helium, N2, Argon |
|
Calibration Gas : 100 ppm Chlorine in N2 |
Nuclear Counter |
10% CH4 in Argon, 1.3% Butane in Helium, 1.5% Propane in Helium |
Inductively Coupled Plasma |
Carrier Gas : Argon 5.0 and Liquid |
Type of Analyser / Instruments |
Type of Gas Required |
Emission from Combustion Engines and Furnaces |
Calibration Gas Mixture |
Industrial Discharge |
PROGAS INSTRUMENT GRADE |
Toxic Component in working place |
|
Type of Analyser / Instruments |
Type of Gas Required |
Engine Tuning |
Calibration Gas Mixture |
Auto Emission Testing |
PROGAS INSTRUMENT GRADE |
|
Exhaust Emission & Atmosphere Pollution Control Gas Mixtures |
|
CO in N2 |
|
CO2 in N2 |
|
Nitric Oxide in N2 |
|
Nitrogen Dioxide in N2 |
|
Sulphur Dioxide in N2 |
|
Hexane in N2 |
|
Propane in N3 |
|
Propane + CO in N2 |
|
Propane + CO + CO2 in N2 |
|
CO + CO2 in N2 |
|
Hydrocarbon + CO2 + Nitric Oxide + CO2 in Purified Air |
|
Hydrocarbon + CO + Nitric Oxide + CO2 in Purified Air |
|
Fuel Gas : Hydrogen in Air, Hydrogen in Helium CO2 + CO + Propane in N2 |
Type of Analyser / Instruments |
Type of Gas Required |
Blood Gas Analyser |
Calibration Gas Mixture |
Pulmonary Function Test |
PROGAS INSTRUMENT GRADE |
Oxygen Uptake |
Blood Gas Analysis Mixtures |
Biological Usage |
Carbon Dioxide + N2 |
Clinical Use |
CO2 + O2 |
Eximer Laser for eye surgery |
CO2 + O2 + N2 Instead of 4% CO+4.5% CO2+13.5% N2+BalanceHe |
Lung Diffusion Test Mixtures |
1000 PPM CO in O2 / N2 Mixtures. Instead of 0.27%CO+14% Helium+21% oxygen+64.73% Nitrogen |
Biological Atmospheres |
|
Anaerobic Growth Mixtures |
|
|
H2 + CO2 + N2 |
Aerobic Growth Mixtures |
CO2 + O2 |
Pulmonary Function Test Mixtures |
CO + Helium + Oxygen + N2 Bal |
Type of Analyser / Instruments |
Type of Gas Required |
Flue Gas Analyser |
Calibration Gas Mixture |
Off Line Gas Chromatograph |
PROGAS INSTRUMENT GRADE |
On Line Analyser for Stack Monitoring |
|
Turbine Maintenance |
Process Gas Mixture |
Type of Analyser / Instruments |
Type of Gas Required |
Flue Gas Analyser |
Calibration Gas Mixture |
Auto Emission Testing |
PROGAS INSTRUMENT GRADE |
On Line Analyser for Stack monitoring |
Process Gas Mixture |
Turbine Maintenance |
Methane + N2 |
|
H2 + Helium |
|
CO2 + CO + N2 |
|
CO2 + CO + Methane + Argon + N2 + H2 |
|
Ethylene + Argon + Ethane + Methane + CO + CO2 = N2 = H2 |
|
1- Butane + N- Butane + 1- Pentane + N- Pentane + N2 + Propane + CO2 + Ethane + Methane |
|
400 PPM CO2 + 5 PPM CO + 30 PPM Methane + N2 |
|
Zero Grade N2 |
Type of Analyser / Instruments |
Type of Gas Required |
Sterilisation Equipment |
Process Gas Mixture |
Type of Analyser / Instruments |
Type of Gas Required |
CO2 Laser Cutting |
Process Gas Mixture |
Marking, Coding, Engraving |
PROGAS INSTRUMENT GRADE |
Eximer Laser for Eye Surgery |
|
Type of Analyser / Instruments |
Type of Gas Required |
Annealing Furnace to Create Reducing Atmosphere |
Process Gas Mixture |
|
Hydrogen in Nitrogen |
|
CO + O2 in Nitrogen |
|
CO2, CO, O2, H2, Air in Nitrogen |
Type of Analyser / Instruments |
Type of Gas Required |
Filling of Tube Lights/Bulbs |
|
Krypton Filled Bulbs |
Nitrogen in Argon |
|
Tube Light Argon |
|
Krypton in Argon |
|
Neon in Argon |
|
Krypton |
Type of Analyser / Instruments |
Type of Gas Required |
Instrument Calibartion |
Oxygen in Nitrogen |
Online Analyser |
CO in Nitrogen |
|
Methane in Argon |
|
Pure Nitrogen |
|
CO + Oxygen + Nitrogen |
|
Hydrogen in Nitrogen |
Type of Analyser / Instruments |
Type of Gas Required |
Ripening of Fruits |
N2 + CO in Oxygen |
Purging / Cleaning |
Nitrogen in CO2 |
Packing of Food |
CO2 in Oxygen |
|
O2 + N2 in CO2 |
|
Pure Nitrogen |
|
Ethylene Balance Nitrogen |
|